Manganese dioxide-gold nanoparticle synergistic platform for sensitive colorimetric detection of creatinine in clinical samples
Authors: Jeber, Jalal N; Kamel, Azhar; Abed, Maher Ahmed; Jasim, Aktham N
Source journal: Mikrochimica acta (2026-11-21)
DOI: 10.1007/s00604-026-08582-7
Abstract
A dual-nanoparticle cascade platform is reported that resolves these limitations by architecturally decoupling chemical recognition from optical transduction, thereby achieving both high selectivity and intrinsic matrix tolerance in a single colorimetric format. The platform couples delta-MnO(2) nanosheets, acting as a surface-selective nanozyme, with citrate-stabilised gold nanoparticles (AuNPs) as the plasmonic transducer. In the first step, creatinine undergoes a two-electron oxidation at the surface Mn(IV) sites of delta-MnO(2) nanosheets, yielding N-methylhydantoin with stoichiometric release of Mn(2+) (1:1 molar ratio confirmed by LC-MS/MS and ICP-MS). The liberated Mn(2+) ions subsequently displace the citrate stabilising layer of the AuNPs and compress their electrical double layer, triggering irreversible colloidal aggregation and a near-infrared shift of the localised surface plasmon resonance from 522 nm to 700 nm. This 700 nm detection window lies entirely beyond the absorption bands of the major serum chromophores, oxyhaemoglobin (415, 541, 577 nm) and bilirubin (450 nm), providing intrinsic spectral immunity to haemolytic and icteric interference without any sample pre-treatment. Under optimised conditions (MES buffer, pH 6.5; 60 degrees C, 10 min), the assay exhibits linearity over 26-535 microM (R(2) = 0.9915), a limit of detection of 8.58 microM, and intra- and inter-assay precision of 1.9-7.4% and 2.1-8.1% RSD, respectively, with mean spike recovery of 99.4-103.6% in matrix-matched pooled human serum. The selectivity against twenty-six endogenous and exogenous interferents, including the four major serum proteins (albumin, IgG, transferrin, fibrinogen), five clinically relevant antibiotic classes (cephalosporin, penicillin, aminoglycoside, fluoroquinolone, glycopeptide), and structural analogues such as creatine, was quantified; only L-cysteine and dopamine produced deviations exceeding 10%, both of which were fully suppressed by N-ethylmaleimide pre-treatment without affecting creatinine recovery. Prospective evaluation against 120 clinical serum specimens, spanning healthy controls (n = 20), CKD stages 1-2 (n = 25), CKD stage 3 (n = 25), CKD stages 4-5 (n = 25), acute kidney injury (n = 15), and hemolytic/icteric samples (n = 10) which demonstrated excellent agreement with the enzymatic reference analyser (Pearson r = 0.997; Passing-Bablok slope = 1.024, intercept = - 3.5 microM; 94.2% of data points within Bland-Altman +/- 1.96 SD limits of agreement). Subgroup-stratified recovery analysis showed no significant inter-subgroup differences (F(5,114) = 0.83, p = 0.53), and CKD staging concordance with the enzymatic reference reached 100% across all 95 CKD/AKI specimens. Six independent sensor preparations synthesised on different days yielded an inter-batch calibration-slope RSD of 2.5%, with no statistically significant inter-batch differences (one-way ANOVA, F(5,24) = 1.96, p = 0.12); a 180-day storage-stability study supported an in-use shelf-life of 120 days at 4 degrees C with full spike-recovery retention (95-105% throughout); and 50 consecutive measurements in a single working day yielded 1.7% within-run RSD with no detectable drift. Requiring only 5 microL of serum, yielding results within 10 min, and costing less than $0.08 per test, this nanozyme-plasmonic architecture offers a robust, low-cost, and interference-resistant alternative to conventional creatinine assays in central and decentralised clinical laboratories. While the present implementation requires a 60 degrees C heating block and a spectrophotometric reader and therefore does not yet satisfy all WHO ASSURED criteria for fully equipment-free point-of-care use, the underlying chemistry, low reagent cost and minimal sample volume make it an attractive candidate for subsequent translation to lyophilised reagent strips with smartphone-based readout.
Related topics
Related open access articles
- A simple and effective fluorescent and colorimetric probe for the detection of glutathione in human serum
- Emerging mycotoxins in botanicals: benefit and risk
- A Brief Review on Core/shell Quantum Dots
- In vitro cytotoxicity studies on galactosylated chitosan nanoparticles for the delivery of oridonin to liver
- Separation of Six Lupane-Type Triterpenoid Saponins from Leaves of Acanthopanax gracilistylus by HSCCC with Preparative-HPLC
- Chemical characterization of polyphenol extracts from Andean and industrial Solanum tuberosum tubers and their cytotoxic activity on human hepatocarcinoma cells
Abstract and bibliographic data from PubMed (U.S. National Library of Medicine). Copyright of the abstract belongs to the original publisher or authors.