Monoflange Versus Multiflange: Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty

Authors: Babasiz, Mari; Zellner, Alberto Alfieri; Babasiz, Tamara; Assaf, Elio; Froschen, Frank Sebastian; Strauss, Andreas Christian; Wirtz, Dieter Christian; Jaenisch, Max

Source journal: The Journal of arthroplasty (2026-11-16)

DOI: 10.1016/j.arth.2026.11.058

Abstract

BACKGROUND: Severe acetabular bone loss remains a major challenge in hip reconstruction. Custom-made acetabular components (CMACs) represent a valuable treatment option, with monoflange designs potentially offering advantages over multiflange constructs by reducing implant size and soft-tissue exposure while maintaining mechanical stability. METHODS: This retrospective, single-center study analyzed 154 CMACs (101 monoflange and 53 multiflange) and assessed clinical outcomes (Oxford Hip Score), radiographic findings, complications, implant survival, and revision procedures. The mean follow-up was 37.0 months (range, 6.2 to 168.2), with longer follow-up for multiflange than monoflange constructs (55.5 versus 27.3 months; P = 0.011). RESULTS: Monoflange constructs showed shorter hospital stays (P = 0.030), reduced blood losses (P < 0.001), and shorter operative times (P = 0.006). Both groups improved in Oxford Hip Score (OHS), with higher postoperative scores for monoflange constructs (P = 0.010), although adjusted mean change in OHS did not differ (P = 0.566). Periprosthetic joint infection rates were higher for multiflange constructs (18.9 versus 6.9%; P = 0.034). Complete osseointegration was achieved in 93.1% of monoflange and 67.9% of multiflange constructs (P < 0.001). Horizontal center of rotation restoration was comparable (0.9 +/- 5.0 versus 2.0 +/- 5.7 mm; P = 0.236), whereas monoflange constructs showed less cranialization (3.5 +/- 4.5 mm versus 7.6 +/- 5.6 mm; P < 0.001). Multiflange design was associated with a higher risk of implant removal (odds ratio = 4.42; P = 0.007). CONCLUSION: Monoflange CMACs demonstrated favorable clinical and radiographic outcomes and, after adjustment for patient factors, a significantly lower risk of implant removal than multiflange constructs. As implant design and era are confounded in this cohort, these findings should be interpreted as associations and require confirmation in prospective series.

Read the full text

Related topics

Related open access articles

Abstract and bibliographic data from PubMed (U.S. National Library of Medicine). Copyright of the abstract belongs to the original publisher or authors.