Occult Patent Foramen Ovale Causing Severe Refractory Hypoxemia After Acute Type A Aortic Dissection Repair

Authors: Chaubey, Sanjay; Mendpara, Vaidehi; Alqahtani, Mohammad; Skubas, Nikolaos J; Gillinov, Marc; Pasic, Miralem

Source journal: JACC. Case reports (2026-11-03)

DOI: 10.1016/j.jaccas.2026.111013

Abstract

BACKGROUND: After surgery for acute type A aortic dissection, pulmonary function can be reduced because of several possible causes. It is necessary to identify the main cause. CASE SUMMARY: A patient experienced refractory hypoxemia following type A aortic dissection repair. Despite proper respiratory and inotropic support, and near-normal chest imaging, severe hypoxia persisted. Echocardiography revealed an occult patent foramen ovale (PFO) with significant right-to-left shunting, driven by positive-pressure mechanical ventilation and elevated right-sided cardiac pressures. Percutaneous transcatheter closure immediately improved oxygenation, enabling successful ventilator weaning. DISCUSSION: Occult PFO should be suspected in unexplained postsurgical hypoxemia. Early echocardiographic evaluation and prompt percutaneous closure can rapidly reverse hypoxia, preventing prolonged mechanical ventilation and secondary complications. TAKE-HOME MESSAGES: Persistent refractory hypoxemia after acute type A aortic dissection repair is not always pulmonary in origin. Occult PFO should be suspected and early echocardiographic confirmation with prompt PFO closure can produce immediate clinical improvement.