Respiratory-synchronized ultrasound localization microscopy with accelerated motion correction for free-breathing microvascular imaging
Authors: Du, Bingze; Gong, Xinyue; Zhang, Teng; Hao, Ruijinlin; Zhou, Tao; Wu, Jun; Zhu, Yifei; Zhang, Guofeng; Shen, Qinghuan; Xue, Honghui; Xu, Qingsong; Hao, Yu; Ding, Bo; Gu, Zhuxiao; Xu, Huan; Zhang, Dong; Tu, Juan
Source journal: Ultrasonics (2026-11-20)
DOI: 10.1016/j.ultras.2026.108390
Abstract
High-resolution microvascular imaging of moving abdominal organs remains challenging because ultrasound localization microscopy (ULM) requires the accumulation of microbubble events over many respiratory cycles, whereas natural breathing can shift the imaging plane. We present a respiratory-synchronized ULM framework for free-breathing abdominal microvascular imaging. It repurposes the established concept of image-intrinsic respiratory phase recognition as a phase-specific super-resolution reconstruction mechanism for free-breathing ULM, thereby reducing respiratory motion-related vascular blurring. The method combines continuous high-throughput ultrafast ultrasound data recording, image-derived respiratory phase separation, and physiology-guided key-frame motion estimation. By turning respiratory motion from an imaging obstacle into an internal synchronization signal, the framework extracts a surrogate respiratory waveform directly from the recorded ultrasound sequence by zero-mean normalized cross-correlation. Low-motion frame blocks at end-expiration and end-inspiration are selected and reconstructed separately, enabling improved phase-consistent microvascular map reconstruction. To reduce the computational burden of residual motion compensation, displacement fields are estimated from temporally downsampled key frames at a sampling rate determined by physiological motion frequency and interpolated for the remaining frames. The proposed framework enabled phase-specific vascular map reconstruction under natural respiration, reduced mean vessel root-mean-square width by 30.96 %, and increased contrast-to-noise ratio by 77.76 %. Key-frame motion correction achieved an average speedup factor of 8.82 +/- 1.88 across the three kidney datasets and a 7.49-fold speedup in the liver dataset. Instead of relying on breath-holding, external respiratory monitoring, or invasive organ stabilization, this work provides a practical route toward physiology-synchronized super-resolution microvascular imaging of moving abdominal organs.
Related topics
Related open access articles
- Perioperative Compartment Syndrome After Free Flap Reconstruction: A Case Report and Review of the Literature
- Paleokinematic reconstruction and wellbore breakout analysis of in situ stress orientation in a Niger Delta Oilfield: Implications for tectonic reactivation in Nigeria
- Successful perineum and scrotal reconstruction after Fournier gangrene using rotation of a medial thigh fasciocutaneous flap. Report of a case in low-resource settings and literature review
- CHALLENGES IN THE DIAGNOSIS AND TREATMENT OF PATIENTS WITH COLORECTAL CANCER AND COVID-19 COINFECTION - CASE REPORT
- Facing COVID-19 via anti-inflammatory mechanism of action: Molecular docking and Pharmacokinetic studies of six anti-inflammatory compounds derived from Passiflora edulis
- Computational analysis by molecular docking of thirty alkaloid compounds from medicinal plants as potent inhibitors of SARS-CoV-2 main protease
Abstract and bibliographic data from PubMed (U.S. National Library of Medicine). Copyright of the abstract belongs to the original publisher or authors.