Single-sample-calibrated image-derived pharmacokinetics of the PD-L1-targeted tracer [(68)​Ga]Ga-NOTA-SNA002 using total-body PET: Beyond conventional venous blood sampling

Authors: Zhang, Lichao; Xie, Yunze; Tang, Wenxin; Yang, Runjun; Vigne, Jonathan; Nardo, Lorenzo; Besson, Florent L; Rominger, Axel; Hong, Qunying; Liu, Guobing; Shi, Hongcheng

Source journal: European journal of nuclear medicine and molecular imaging (2026-11-24)

DOI: 10.1007/s00259-026-08298-z

Abstract

PURPOSE: To evaluate the feasibility and additional value of total-body PET image-derived pharmacokinetics over venous blood-sampling method in investigating non-tumor tissue and lesion kinetics of the PD-L1-targeted tracer [(68)​Ga]Ga-NOTA-SNA002 in patients with malignant tumors. METHODS: Patients with solid tumors underwent a 60-min dynamic total-body PET acquisition following [(68)​Ga]Ga-NOTA-SNA002 injection, and a 20-min static scan at 120 min post-injection, accompanied by serial venous blood sampling. Systemic PK parameters were estimated via noncompartmental analysis based on time-concentration curves from venous blood sampling and image-derived venous vascular regions using a single-sample calibration, and the PK parameters obtained from the two methods were compared. To characterize kinetic parameters, time-activity curves (TACs) of non-tumor tissues and lung lesions were fitted using compartment models. Lesions' kinetic metrics and standardized uptake value (SUV) were compared after stratification by tumor proportion score (TPS; /= 50%). RESULTS: Image-derived maximum concentration (C(max)) was significantly higher and time to C(max) (T(max)) was significantly shorter than those obtained from venous blood sampling. No significant between-method differences were observed for the remaining PK parameters, except SVC-derived clearance (CL; 2.35 +/- 0.69 vs. 2.69 +/- 0.90 L/h, P = 0.016). The relative differences were within 18% for right atrium (RA) and within 19% for superior vena cava (SVC) for these parameters. Lesions with high TPS (>/= 50%) demonstrated significantly elevated K(1) (0.51 +/- 0.17 vs. 0.11 +/- 0.09 mL/cm(3)/min, P = 0.009) and k(2) (6.06 +/- 1.76 vs. 2.19 +/- 1.60 min(-1), P = 0.009) compared to those with low TPS (< 50%). Additionally, dynamic [(68)​Ga]Ga-NOTA-SNA002 PET provided information on tracer retention in non-tumor tissues and lesions. CONCLUSION: Total-body dynamic PET imaging with a single-sample calibration provides PK data comparable to conventional venous blood sampling while simultaneously characterizing tissue kinetic profiles throughout the body. Additionally, these kinetic parameters may offer complementary value for the stratification of lesion-level PD-L1 expression and the preliminary assessment of immunotherapy response. CLINICAL TRIAL REGISTRATION: This phase I clinical trial was approved by the National Medical Products Administration of China and was registered at www.chinadrugtrials.org.cn (registry number: CTR20232251).

Read the full text

Related topics

Related open access articles

Abstract and bibliographic data from PubMed (U.S. National Library of Medicine). Copyright of the abstract belongs to the original publisher or authors.