Sustained reduction of blood culture contamination with a dedicated phlebotomy team
Authors: Kim, Nak-Hyun; Ahn, Soyeon; Lee, Hyunju; Shin, Dong Woo; Choi, Eun Young; Lim, Younghee; Choi, Yunsang; Choi, Seong Jin; Moon, Song Mi; Song, Kyoung-Ho; Kim, Eu Suk; Kim, Hong Bin; Park, Jeong Su
Source journal: Microbiology spectrum (2026-11-20)
DOI: 10.1128/spectrum.02570-26
Abstract
Blood culture contamination and inadequate fill volumes compromise the diagnosis of bloodstream infections. While dedicated phlebotomy teams improve these metrics, evidence regarding long-term sustainability is scarce. We evaluated the impact of a 24/7 dedicated phlebotomy team on blood culture quality using a 9-year longitudinal data set. In this retrospective cohort study at a 1,300-bed tertiary hospital, we analyzed 505,752 adult blood culture sets collected between 2015 and 2023. Following the transition to a dedicated phlebotomy team in March 2017 in all clinical units except the emergency room (ER), we evaluated the intervention's effect using difference-in-differences (DID) analyses, with cultures collected by non-dedicated ER staff serving as a concurrent control. The dedicated team demonstrated a significantly lower contamination rate (0.22% [586/261,480]) than concurrent non-dedicated staff (0.80% [1,171/145,772]; P < 0.001), corresponding to a 56.6% reduction in the adjusted odds of contamination in the general wards (adjusted odds ratio = 0.43; P < 0.001). Mean fill volume per bottle was higher for the dedicated team (4.61 mL vs 2.16 mL; P < 0.001). Although the overall true positivity rate was lower for the dedicated team (6.24% vs 8.89%, P < 0.001), unit-stratified and DID analyses indicated a composition effect driven by higher baseline positivity in the ER, where non-dedicated staff predominantly operated. Within the same units, true positivity did not decrease after implementation. Trajectory analysis revealed that individual contamination rates stabilized after 13 months of continuous service. Sustained, negligible contamination rates and improved fill volumes are achievable through proficiency from dedicated training and long-term retention of specialized personnel. IMPORTANCE: Contaminated blood cultures and poor sample volumes significantly compromise diagnostic accuracy, patient safety, and antimicrobial stewardship. While dedicated phlebotomy teams are widely recommended to mitigate these preanalytical errors, evidence regarding their long-term durability and the time required for personnel to achieve technical proficiency remains limited. In this 9-year study of over half a million blood cultures, we demonstrate that a dedicated team effectively minimizes contamination by skin bacteria and optimizes blood volumes for detecting bloodstream pathogens. Uniquely, our trajectory analysis reveals a 13-month learning curve required for personnel to achieve this high level of technical proficiency. These findings emphasize that maximizing diagnostic certainty requires hospitals to not only deploy specialized collection teams but also actively prioritize staff retention.
Related topics
Related open access articles
- Obliging Tactics to Mitigate the Intricate Problem of Aflatoxin Contamination in Peanut: A Review
- Urban sediment contamination with heavy metals and organic matter in Southern China
- HEAVY METALS CONCENTRATION AND POLLUTION ASSESSMENT OF THE BEACH SEDIMENTS IN LAGOS, SOUTHWESTERN NIGERIA
- Distribution of Cs-137 and dose rate investigation in the terrestrial environment of Jamaica
- Effect of pollution on the fluctuating asymmetry in the grass goby Zosterisessor ophiocephalus Pallas, 1811 as contamination indicator of Eastern Tunisia.
- EFFECT OF IN VIVO CONTAMINATION BY EFFLUENT FROM PHOSPHATE TREATMENT INDUSTRY ON THE CLAM RUDITAPES DECUSSATUS
Abstract and bibliographic data from PubMed (U.S. National Library of Medicine). Copyright of the abstract belongs to the original publisher or authors.